Home > Auto Compressors > Bus & Truck & Farm compressor >

BOCK FK40 COMPRESSOR made in China

Categories

BOCK FK40 COMPRESSOR made in China

BOCK FK40 COMPRESSOR made in China
BOCK FK40 COMPRESSOR made in China
CategoriesBus & Truck & Farm compressor
BrandINTL Auto Air Conditioning Compressor
ModelINTL-XZC453
Size48*43*41CM
TypeCompressor
Car MakeBUS
OE NO.BOCK FK40
WARRANTEEBRAND NEW
WEIGHT36KG
FOB portHuangpu
Terms of PaymentWestern Union,T/T,Paypal
Download DOC
Update Time07-25-2017
Detail Information

We are factory that can offer all kinds of car a/c compressor with high quality and competitive price, welcome inquiry !


INTL MODEL:INTL-XZC453


BOCK FK40 COMPRESSORBOCK FK40 COMPRESSORBOCK FK40 COMPRESSORBOCK FK40 COMPRESSORBOCK FK40 COMPRESSOR

Advantage:


1. Compact structure, Low weight   2. Innovated design, Long life service   3. New technology, High efficiency
Character:


1. Special pressure balance bypass prevent lube oil into inside, the efficiency much better.


2. Patented infiltrated ceramic piston ring without gap at joint prolongs the service life.


3. unitary body cast by Aluminum Alloy with optimum heat transfer

ModelCylindersDischarge VolumeLube Volume/ModelRotation Speed
(rpm)
Pipe SizeWeightElectro Magnetic Clutch
(accessory)
Discharge Pipe(mm)Air Struction Pipe(mm)

655N  

655K

46502L/RL68500-3000283533Pressure 24V
Power 60W

560N  

560K

5542835
470N               470K4662228
390N    390K3852228

Limits of application


Evap oration temperature to min.=-30°C


Condensing temperature tc max.=+70°C


Discharge end temperture tv2 max.=+140°C


Rotation speed n max.[rpm]:see Specifications


Rotation speed n min.[rpm]:see Specifications


Operating overpressure HD(HP)PV2 max.=25 bar


Operating overpressure ND(LP)PV1 max.=19 bar


Explanation


INTL-40 Compressors can be operated in the range of the diagram above.


No supplementary cooling is necessary for operation within the non-shaded area.


Supplementary cooling is only necessary in the vertical shaded area when the suction gas superheat exceeds 20K.


The following applies if operation proves necessary within this range:


It is advisable to use a thermal protective thermostat(accessory).


Only highly thermostable oils are to be used


If capacity regulators are temperature may prove necessary.Individual setting necessary(the max. discharge end

temperature of +140°C must not be exceeded).

BOCK FK40 COMPRESSORBOCK FK40 COMPRESSORBOCK FK40 COMPRESSORBOCK FK40 COMPRESSOR

Please send your message to us
*We will reply your inquiry to this Email as soon as we see it
E-mail
 
/
Title
Content

Agree to use terms of service